Product Information
Product Name: Chevron Techron Concentrate Plus
Form: liquid
Product Category: Auto Products » treatment » Fuel System & Air Intake
Customer Service: 800-582-3835
Date Verified: 2011-03-04
Date Entered: 2011-04-04
Related Items: Products with similar usage in this database
Manufacturer
Manufacturer: Chevron Texaco
Address: 6001 Bollinger Canyon Road
City: San Ramon
State: CA
Zip Code: 94583
Telephone Number: 800-582-3835
Toll Free Number: 800-582-3835
Date Info Verified: 2011-04-04
Related Items: Products by this manufacturer
The following information (Health Effects, Handling/Disposal, and Ingredients) is taken from the product label and/or the Material Safety Data Sheet (MSDS) prepared by the manufacturer. The National Library of Medicine does not test products nor does it evaluate information from the product label or the MSDS. (What is an MSDS?) (Complete MSDS for this product)
Health Effects
Enter text or highlight term...
Warnings: DO NOT USE OR STORE near heat, sparks, flames, or hot surfaces . USE AND STORE ONLY IN WELL VENTILATED AREA. Keep container closed when not in use.
Acute Health Effects: From MSDS:Hazards IdentificationEmergency Overview: Combustible liquid and vapor. May cause respiratory tract irritation if inhaled. May cause lung damage if swallowed. May cause dizziness, drowsiness and reduced alertness. Causes skin irritation. Toxic to aquatic organisms. May cause long-term adverse effects in the aquatic environment.Potential Health EffectsEye contact: Not expected to cause prolonged or significant eye irritation.Skin contact : Contact with the skin causes irritation. Skin contact may cause drying or defatting of the skin. Contact with the skin is not expected to cause an allergic skin response. Symptoms may include pain, itching, discoloration, swelling, and blistering. Not expected to be harmful to internal organs if absorbed through the skin. High-Pressure Equipment Information: Accidental high-velocity injection under the skin of materials of this type may result in serious injury. Seek medical attention at once should an accident like this occur. The initial wound at the injection site may not appear to be serious at first; but, if left untreated, could result in disfigurement or amputation of the affected part.Ingestion: Because of its low viscosity, this material can directly enter the lungs, if swallowed, or if subsequently vomited. Once in the lungs it is very difficult to remove and can cause severe injury or death. May be irritating to mouth, throat, and stomach. Symptoms may include pain, nausea, vomiting, and diarrhea.Inhalation: The vapor or fumes from this material may cause respiratory irritation. Symptoms of respiratory irritation may include coughing and difficulty breathing. Excessive or prolonged breathing of this material may cause central nervous system effects. Central nervous system effects may include headache, dizziness, nausea, vomiting, weakness, loss of coordination, blurred vision, drowsiness, confusion, or disorientation. At extreme exposures, central nervous system effects may include respiratory depression, tremors or convulsions, loss of consciousness, coma or death.
Chronic Health Effects: From MSDS:No information provided.
Carcinogenicity: Not listed by IARC or NTP.
First Aid: Eye: No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.Skin: Wash skin with water immediately and remove contaminated clothing and shoes. Get medical attention if any symptoms develop. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.Ingestion: If swallowed, get immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person.Inhalation: Move the exposed person to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention if breathing difficulties continue. Move the exposed person to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention if breathing difficulties continue or if any other symptoms develop.Note to Physicians: Ingestion of this product or subsequent vomiting may result in aspiration of light hydrocarbon liquid, which may cause pneumonitis. In an accident involving high-pressure equipment, this product may be injected under the skin. Such an accident may result in a small, sometimes bloodless, puncture wound. However, because of its driving force, material injected into a fingertip can be deposited into the palm of the hand. Within 24 hours, there is usually a great deal of swelling, discoloration, and intense throbbing pain. Immediate treatment at a surgical emergency center is recommended.
Health Rating: 2
Flammability Rating: 2
Reactivity Rating: 0
HMIS Rating Scale: 0 = Minimal; 1 = Slight; 2 = Moderate; 3 = Serious; 4 = Severe; 
N = No information provided by manufacturer; * = Chronic Health Hazard
MSDS Verified Date: 2011-03-04
MSDS Date: 2011-03-31
Handling/Disposal
Handling: Liquid evaporates and forms vapor (fumes) which can catch fire and burn with explosive force. Invisible vapor spreads easily and can be set on fire by many sources such as pilot lights, welding equipment, and electrical motors and switches. Fire hazard is greater as liquid temperature rises above 29 degrees C (85 degrees F). Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Do not breathe vapor or fumes. Wash thoroughly after handling.Avoid contaminating soil or releasing this material into sewage and drainage systems and bodies of water.Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures. DO NOT USE OR STORE near heat, sparks, flames, or hot surfaces . USE AND STORE ONLY IN WELL VENTILATED AREA. Keep container closed when not in use.
Disposal: Use material for its intended purpose or recycle if possible. This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by US EPA under RCRA (40 CFR 261) or other State and local regulations. Measurement of certain phys
Ingredients from MSDS/Label
ChemicalCAS No / Unique IDPercent
Trade secret or proprietary formula000000-02-130-60
1,2,4-Trimethylbenzene000095-63-61.0-5.0
Stoddard solvent008052-41-315-40
Distillates, petroleum, hydrotreated light064742-47-840-70
Solvent naphtha, petroleum, light aromatic064742-95-65.0-10.0
(Complete MSDS for this product)
HHS.GOV Household Products Database Home Page National Institutes of Health National Library of Medicine Specialized Information Services National Library of Medicine