Product Name: CRC Industrial Roll-Up Door Lubricant 03029, Aerosol, Professional Use
Form: aerosol
Product Category: Commercial / Institutional » multipurpose » Lubricant
Customer Service: 800-272-8963
Date Entered: 2014-01-03
Related Items: Products with similar usage in this database
Manufacturer
Manufacturer: CRC Industries, Inc.
Div., Berwind Corp.
Address: 800 Enterprise Road Suite 101
City: Horsham
State: PA
Zip Code: 19044
Telephone Number: 215-674-4300
Fax Number: 800-272-4560
Toll Free Number: 800-556-5074
Date Info Verified: 2019-01-16
Related Items: Products by this manufacturer
The following information (Health Effects, Handling/Disposal, and Ingredients) is taken from the product label and/or the (Material) Safety Data Sheet, (M)SDS, prepared by the manufacturer. The National Library of Medicine does not test products nor does it evaluate information from the product label or the (M)SDS. (What is an (M)SDS?) (Complete (M)SDS for this product)
Health Effects
Enter text or highlight term...
Warnings: Do not puncture, incinerate or store above 120 deg F. Exposure to high temperatures may cause can to burst. Do not place in direct sunlight or near any heat source. Aerosol cans will conduct electricity. Keep away from all live electrical sources including battery terminals, solenoids, electrical panels and other electronic components. Failure to observe this warning may result in serious injury from flash fire and/or electrical shock. Use only in well ventilated area. Ventilation may be improved by opening a window or door or providing mechanical assistance. Avoid continuous breathing of vapor and spray mist. Avoid contact with skin and eyes. If ventilation is not adequate, respiratory protection should be worn.
Acute Health Effects: From MSDS

Hazards Identification

Emergency Overview

Flammable. Harmful or Fatal if Swallowed. Contents Under Pressure.

Potential Health Effects

Eye Contact: Contact may cause mild irritation including stinging, watering and redness.

Skin Contact: Contact may cause redness, itching, burning and skin damage. Prolonged or repeated contact can worsen irritation and lead to dermatitis. No harmful effects from skin absorption are expected.

Inhalation: Expected to have a low degree of toxicity by inhalation. High concentrations of vapors may be irritating to the respiratory tract, and may cause headaches, dizziness, anesthesia, drowsiness, and other central nervous system effects.

Ingestion: Small amounts of this product aspirated into the respiratory system during ingestion or vomiting may cause mild to severe pulmonary injury, possibly progressing to death.

Medical Conditions Aggravated by Exposure: Pre-existing dermatitis
Chronic Health Effects: From MSDS:

Not known.
Carcinogenicity: Not listed by IARC, OSHA and NTP.
First Aid: Eye Contact: Immediately flush with plenty of water for 15 minutes. Call a physician if irritation persists.

Skin Contact: Remove contaminated clothing and wash affected area with soap and water. Call a physician if irritation persists. Wash contaminated clothing prior to re-use.

Inhalation: Remove person to fresh air. Clear air passage if blocked. Keep person calm. If not breathing, give artificial respiration. If breathing is difficult give oxygen. Call a physician.

Ingestion: If swallowed, do NOT induce vomiting. Keep at rest. Get prompt medical attention.

Note to Physicians: This product is an aspiration hazard.
Health Rating: 1
Flammability Rating: 2
Reactivity Rating: 0
HMIS Rating Scale: 0 = Minimal; 1 = Slight; 2 = Moderate; 3 = Serious; 4 = Severe; 
N = No information provided by manufacturer; * = Chronic Health Hazard
MSDS Date: 2013-03-28
Handling/Disposal
Handling: Do not use near an open flame, heat or other sources of ignition. Use caution around energized equipment. The metal container will conduct electricity if it contacts a live source. This may result in injury to the user from electrical shock and/or flash fire.Store in a cool dry area out of direct sunlight. Aerosol cans must be maintained below 120 deg F/49 deg C to prevent cans from rupturing.
Disposal: The dispensed liquid product is not a RCRA hazardous waste. Empty aerosol containers may be recycled. All disposal activities must comply with federal, state, provincial and local regulations. Local regulations may be more stringent than state, provincial or national requirements.
Ingredients from (M)SDS/Label
ChemicalCAS No / Unique IDPercent
Carbon dioxide000124-38-91.0-5.0
Solvent-refined heavy paraffinic distillate064741-88-415.0-25.0
Distillates, petroleum, hydrotreated light064742-47-865.0-75.0
Corrosion inhibitor(s)999999-51-25.0-15.0